Using Steps and selection considerations of nebulizer with mouth piece
What steps do I need to follow when using a nebulizer with mouth piece? What should I pay attention to when choosing a nebulizer with mouth piece? Let's take a look at the using step of the nebulizer with mouth piece and the selection precautions, I hope to help everyone.
Using step of nebulizer with mouth piece
1. Add 250ml of cold distilled water to the water tank, and the liquid level should be about 3cm to immerse the sound-permeable membrane at the bottom of the atomized tank.
2. Put the liquid in the atomization tank, dilute to 30-50ml, screw the lid, put the nebulizer with mouth piece into the sink, and close the lid.
3. Turn on the power, first turn on the power switch, the red indicator light is on, preheat for 3 minutes, then turn on the atomization switch, the white indicator light is on, and the liquid is sprayed in a mist.
4. Adjust the amount of mist as needed, inhale, cover the nose and mouth, and open when exhaling; or put the "mouth mouth" into the sick population, and let it close the lips and inhale deeply.
In addition, the general use time is 15-20 minutes, after treatment, first turn off the nebulizer with mouth piece switch with the mouth, then turn off the power switch, otherwise the tube is easy to damage. Finish the contents, pour off the water in the sink, and dry the sink.
selection considerations of nebulizer with mouth piece
1. Vibration: The vibration is accompanied by vibration. Generally speaking, if the noise is large, the vibration must not be small.
2. Noise: The noise level of the nebulizer with mouth piece with a mouth is an important indicator of its quality. It will affect the mood of patients who are not good. The good quality of the nebulizer with mouth piece should be within 65 decibels.
3. Atomized particles: the size is directly related to the atomization effect. The smaller (less than 2.5μm) atomized particles can reach the lower respiratory tract and the alveoli. The specifications provided by the general manufacturer indicate the atomized particle size and atomization. Particle labeling generally involves the size of the granules.
4. fever: with the above noise, vibration, is the problem of heat, noise, vibration, the machine must have more heat.
5. design and appearance quality: atomization cup after the compressor meets the basic requirements, the quality of the atomization cup is especially critical. It is best to choose a patented atomizing cup. This information can generally be obtained from the package with nebulizer with mouth piece.
The above is about the use step of the nebulizer with mouth piece and the selection of precautions. I hope everyone will understand the use step of the nebulizer with mouth piece and the selection of precautions, which will help everyone.